Chemistry Times
Recent News |  Archives |  Tags |  About |  Newsletter |  Submit News |  Links |  Subscribe to ChemistryTimes.com RSS Feed Subscribe
New Articles
New filtering technology has environmental, industrial applications 11/20/2008

Researchers learn how bleach kills bacteria 11/18/2008

Wasabi receptor can sense ammonia that causes pain 11/17/2008

New catalysts promise faster, cleaner and more efficient research platform 11/17/2008

Test identifies toxic platinum and palladium without time-consuming sample pretreatment 11/16/2008

Acrylic glass made of sugar 11/16/2008

Luminescence shines new light on proteins 11/15/2008

The bonsai effect: Wounded plants make jasmonates, inhibiting cell division, stunting growth 11/12/2008

Signaling between protein, growth factor is critical for coordinated cell migration 11/11/2008

Hydrogen tank lighter than battery 11/10/2008

Engineer creating more sensitive, safer landmine detectors 11/7/2008

In decision to grow, bacteria follow the crowd 11/6/2008

Bare bones of crystal growth: Biomolecules enhance metal contents in calcite 11/5/2008

New type of fuel found in Patagonia fungus 11/5/2008

Bacteria manage perfume oil production from grass 11/4/2008

New gas sensor is tiny, quick (1/12/2008)

Tags:
gases, sensors, chromatography, mass spectrometry

MIT research scientist Luis Velasquez-Garcia, left, and Akintunde Ibitayo Akinwande, professor of electrical engineering and computer science, are developing a tiny sensor that can detect hazardous gases, including biochemical warfare agents. Photo / Donna Coveney
MIT research scientist Luis Velasquez-Garcia, left, and Akintunde Ibitayo Akinwande, professor of electrical engineering and computer science, are developing a tiny sensor that can detect hazardous gases, including biochemical warfare agents. Photo / Donna Coveney
Engineers at MIT are developing a tiny sensor that could be used to detect minute quantities of hazardous gases, including toxic industrial chemicals and chemical warfare agents, much more quickly than current devices.

The researchers have taken the common techniques of gas chromatography and mass spectrometry and shrunk them to fit in a device the size of a computer mouse. Eventually, the team, led by MIT Professor Akintunde Ibitayo Akinwande, plans to build a detector about the size of a matchbox.

"Everything we're doing has been done on a macro scale. We are just scaling it down," said Akinwande, a professor of electrical engineering and computer science and member of MIT's Microsystems Technology Laboratories (MTL).

Akinwande and MIT research scientist Luis Velasquez-Garcia plan to present their work at the Micro Electro Mechanical Systems (MEMS) 2008 conference next week. In December, they presented at the International Electronic Devices Meeting.

Scaling down gas detectors makes them much easier to use in a real-world environment, where they could be dispersed in a building or outdoor area. Making the devices small also reduces the amount of power they consume and enhances their sensitivity to trace amounts of gases, Akinwande said.

He is leading an international team that includes scientists from the University of Cambridge, the University of Texas at Dallas, Clean Earth Technology and Raytheon, as well as MIT.

Their detector uses gas chromatography and mass spectrometry (GC-MS) to identify gas molecules by their telltale electronic signatures. Current versions of portable GC-MS machines, which take about 15 minutes to produce results, are around 40,000 cubic centimeters, about the size of a full paper grocery bag, and use 10,000 joules of energy.

The new, smaller version consumes about four joules and produces results in about four seconds.

The device, which the researchers plan to have completed within two years, could be used to help protect water supplies or for medical diagnostics, as well as to detect hazardous gases in the air.

The analyzer works by breaking gas molecules into ionized fragments, which can be detected by their specific charge (ratio of charge to molecular weight).

Gas molecules are broken apart either by stripping electrons off the molecules, or by bombarding them with electrons stripped from carbon nanotubes. The fragments are then sent through a long, narrow electric field. At the end of the field, the ions' charges are converted to voltage and measured by an electrometer, yielding the molecules' distinctive electronic signature.

Shrinking the device greatly reduces the energy needed to power it, in part because much of the energy is dedicated to creating a vacuum in the chamber where the electric field is located.

Another advantage of the small size is that smaller systems can be precisely built using microfabrication. Also, batch-fabrication will allow the detectors to be produced inexpensively.

The research, which started three years ago, is funded by the Defense Advanced Research Projects Agency and the U.S. Army Soldier Systems Center in Natick, Mass.

Note: This story has been adapted from a news release issued by MIT